Next day delivery available! Call 020 3004 5451

Speak to an expert! Call 020 3004 5451

ARC  |  SKU: 48947210158427

ARC Fire Stop Slab - All Thicknesses


VAT and Shipping calculated at checkout.

Contact

Have any questions or need assistance with this product?

Phone: 020 3004 5451

Email: sales@nationalinsulationsupplies.com

Contact us.

Delivery & Shipping

Standard: 5-7 Working Day Delivery

Express: Same/Next Day Delivery - subject to availability, please call: 020 3004 5451

For further information, please see our Delivery & Shipping Policy here.

Returns

This product is a non-returnable product, please see our Return and Refund Policy for further details.

Product Datasheets

Things you should know about this product!

  • This product is priced on application, please get in touch to request a quotation
  • This product is available in the following thicknesses: Up to 50mm, 60mm, 70mm, 80mm, 90mm, 100mm, 110mm, 120mm, 130mm, 140mm, 150mm, 160mm, 170mm, 180mm, 190mm, 200mm, 210mm, 220mm, 230mm, 240mm, 250mm, 260mm, 270mm, 280mm, 290mm, 300mm, 325mm, 350mm, 375mm, 400mm, 425mm, 450mm

Description

ARC Fire Stop Slab offers up to four hours of fire integrity and features a foil-facing that acts as a smoke barrier. It is suitable for both horizontal and vertical applications, and can be cut to size on site or factory finished. Designed to accommodate cavity widths of up to 450mm, it is third-party certificated by IFC and meets EN1366-4 standards. The product is versatile, suitable for use with various substrates including SFS, masonry, and A2 sheathing board. It is particularly effective for external wall cavities at compartment wall and floor junctions, and is ideal for common details at the floor slab where space is limited.

Specifications

  • Length
    1200mm
  • Width
    Varies depending on thickness
  • Material type
    Non-combustible rockfibre mineral wool
  • Thermal conductivity
    0.035W/mK
  • Fire rating
    Euroclass A1

Key Features

  • Provides up to four hours of fire integrity
  • Foil-faced to act as a smoke barrier
  • Suitable for both horizontal and vertical applications
  • Can be cut to size on site or factory-finished
  • Available for cavity widths up to 450mm
  • Third-party certificated by the IFC
  • Compatible with various substrates including SFS, masonry, and A2 sheathing board
  • Tested to EN1366-4 standards
  • Designed for use in external wall cavities at compartment wall and floor junctions
  • Ideal for common details at floor slabs where space is limited

Where to use

Integrity horizontally and vertically within external wall cavities: The ARC Fire Stop Slab is designed to provide essential fire protection in external wall cavities, both horizontally and vertically.

Horizontal and Vertical Fire Integrity: The Fire Stop Slab is engineered to maintain the structural integrity of wall cavities against fire spread. When installed, it acts as a barrier that prevents the passage of fire and smoke through the cavity, addressing both horizontal and vertical fire risks. This dual functionality is crucial in preventing fire from moving across different areas of the building or ascending through wall cavities.

Comprehensive Coverage: By placing the Fire Stop Slab within the external wall cavity, it ensures that any potential gaps or openings are sealed effectively. This comprehensive coverage helps to maintain the compartmentalisation of the building, which is essential for controlling fire spread and protecting different sections of the building from fire damage.

Thermal Insulation: In addition to its fire-stopping capabilities, the Fire Stop Slab also contributes to thermal insulation. It helps to reduce heat transfer through the wall cavity, improving the building’s overall energy efficiency and maintaining a stable indoor temperature.

Compliance with Building Regulations: The ARC Fire Stop Slab meets stringent building regulations for fire safety, ensuring that the wall cavities provide the required level of protection. This compliance is vital for meeting legal requirements and ensuring the safety of occupants in the event of a fire.

Ease of Installation: Designed for ease of use, the Fire Stop Slab can be integrated into the wall cavity installation process without extensive modifications. Its straightforward installation process helps ensure that fire safety measures are effectively implemented during construction.

Frequently asked questions

What is the ARC Fire Stop Slab?

The ARC Fire Stop Slab is a high-density stone wool slab designed to provide effective fire-stopping and acoustic insulation in cavity walls, floors, and other construction applications. It helps to prevent the spread of fire and smoke, ensuring building safety.

What materials are used in the ARC Fire Stop Slab?

The ARC Fire Stop Slab is made from non-combustible stone wool, which provides excellent fire resistance, thermal insulation, and soundproofing properties.

How is the ARC Fire Stop Slab installed?

The ARC Fire Stop Slab is typically friction-fitted into cavities or gaps between structural elements, such as between walls and floors. It can be easily cut to size on-site and installed with minimal need for additional fixings.

In what types of construction projects is the ARC Fire Stop Slab used?

This product is commonly used in both new builds and refurbishment projects, particularly in residential, commercial, and industrial buildings, where fire safety and acoustic insulation are critical.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Maestro
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Compare with similar products

You are currently viewing the first product on this grid:

A table comparing the facets of 1 products
Facet
AIM Fire Stop Strip - 1200mm
View details
Price
Price
Length
Length
1200mm
Width
Width
Up to 400mm
Edge
Edge
n/a
Fire rating
Fire rating
n/a
Compressive strength
Compressive strength
n/a
Thermal conductivity
Thermal conductivity
n/a
Material type
Material type
Stone wool
ARC
ARC Fire Stop Slab - All Thicknesses

Length

1200mm

Width

Varies depending on thickness

Edge

N/A

Fire rating

Euroclass A1

Compressive strength

N/A

Density

N/A

Thermal conductivity

0.035W/mK

Material type

Non-combustible rockfibre mineral wool
View product